Water-cooled Chillers and Heat pumps for Indoor Installation

Water is its element!

As a result of application of water-cooled condensers, units in the GWC and GLWC series are distinguished by structural design that is more compact than the air-cooled series. As a result, they optimally fit into their installation site, since water-cooled chillers have been designed only for indoor installation.

  •  

    GLWC 2015 – 1204 BD2 (43 – 371 kW)

    • Indoor installation
    • Scroll compressor
    • Cooling
    • Refrigerant R-410A
    • Plate heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWC 0401 – 1902 BA2 (87 – 447 kW)

    • Indoor installation
    • Screw compressor
    • Cooling
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWC 1130 – 4960 CA2 (306 – 2416 kW)

    • Indoor installation
    • Screw compressor
    • Cooling
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
    • Unit as high-performance model
  •  

    GLWH 2015 – 1204 BD2 (50 – 419 kW)

    • Indoor installation
    • Scroll compressor
    • Cooling
    • Heating
    • Refrigerant R-410A
    • Plate heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 0401 – 1902 BA2 (97 – 494 kW)

    • Indoor installation
    • Screw compressor
    • Cooling
    • Heating
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 1130 – 4960 CA2 (339 – 2663 kW)

    • Indoor installation
    • Screw compressor
    • Cooling
    • Heating
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 1130 – 4960 CA2.HT (345 – 2581 kW)

    • Indoor installation
    • Screw compressor
    • Cooling
    • Heating
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
    • Unit as high-temperature model

In these ranges of models, plate heat exchangers are employed both as condensers and as evaporators in the smaller and medium performance ranges. In units in the higher performance ranges (up to 2,749 kW), shell and tube heat exchangers are used as condensers and evaporators.

These units have already been optimized with respect to noise-emission behavior. However, some units are also optionally available with additional sound-insulation cladding in order to avoid any disturbing noise inside buildings, shop floors, and halls. In medium and high performance ranges, these units are also available with heat-pump functions.

Contact Us

DencoHappel GmbH

Südstraße 48
44625 Herne
Germany
+49 2325 468-00
+49 2325 468-222
Downloads
Areas of Application
Chillers:
  • GLWC 0152 – 0612 BD2
  • GLWC 0524 – 1204 BD2
  • GLWC 0401 – 0961 BA2
  • GLWC 0802 – 1902 BA2
  • GLWC 1130 – 4960 CA2
Heat pumps:
  • GLWH 0152 – 0612 BD2
  • GLWH 0524 – 1204 BD2
  • GLWH 0401 – 0961 BA2
  • GLWH 0802 – 1902 BA2
  • GLWH 1130 – 4960 CA2
Technical Information and energy label